Operating Conditions

RF Transformers should always operate within safe limits of temperature and linearity. A program which checks for safe operating conditions using FT-140 and FT-240 size cores in HF transformers can be downloaded from: FT core calculation

SIMPLE HF BALUNS FOR 50/75 OHM COAX

The following diagrams and tables show some simple 1:1 and 4:1 baluns for 1.8 - 30 MHz suitable for use up to 200W (400W peak) on systems using 50 or 75 ohm coaxial cable. SWR should not exceed 1.5:1.

Materials required:

Winding Methods

winding method

Examples of winding methods a, b, c, d on a rod.
a b c d

Toroid core with 10 close spaced bifilar turns


1:1 Rod Balun



1:1 balun

Ferrite Rod: R-61-037-300
Construction:
Start by winding a layer of ptfe tape on the rod
Cut two 750mm lengths of 1.25mm ecw for a bifilar winding.
Starting at the centre of the rod, close wind half the length of the wires towards one end. Repeat for the other half. 15 bifilar turns (2 wires) should now be centred on the rod, with sufficient end lengths for terminations.
Cut the spacing twine into 750mm lengths and insert between the wires as required by tightly pulling the cord between the turns. This makes a secure finished winding. Start at the centre of the winding and work towards each end.

For a 50 ohm balun put spacing twine between the bifilar turns (winding method c).
For a 75 ohm balun put spacing twine between all wires (winding method d).

Waterproof, terminate and house the finished balun as required.

See test results for the rod balun.

4:1 Rod Balun



4:1 balun

Ferrite Rod: R-61-037-300
Use the same winding method and materials as in the rod balun above.
Construction:
Cut two 750mm lengths of 1.0mm ecw for a bifilar winding.
Wind 15 bifilar turns centred and close spaced on the rod.
Wind spacing twine between all turns as described above (winding method d).
See test results for this rod balun.

1:1 Toroid Balun



1:1 balun

Ferrite Toroid: FT-140-61.

Use the same winding method and materials as in the rod balun above.
Construction:
Spread the 12 bifilar turns of 1.25mm ecw evenly around the core. This leaves space between the 12 turns.
If the lowest operating frequency is 3.5MHz then 10 turns is sufficient.
For a 50 ohm balun the bifilar pairs are close spaced (winding method a).
For a 75 ohm balun put spacing twine between the bifilar pair(winding method b).
See test results for these toroid baluns.

4:1 Toroid Balun



4:1 balun

Ferrite Toroid: FT-140-61.
Use the same winding method and materials as in the rod balun above.
Construction:
Spread the 12 bifilar turns of 1.25mm ecw evenly around the core. This leaves space between the 12 turns.
If the lowest operating frequency is 3.5MHz then 10 turns is sufficient.
For the 50:200 ohm balun the bifilar pairs are close spaced (winding method a).
For the 75:300 ohm balun put spacing twine between the bifilar pair (winding method b).
See test results for these toroid baluns.